HeatReclaim Ventilation The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly.
Significantreduction in ventilation heat loss due to heat recovery. Humidity balance and regulated air exchange create individually controlled microclimate. MICRA 60. More . MICRA 60 - is the single room air handling unit for balanced energy saving single room ventilation of flats, cottages, social and commercial premises.
andtraining on VRV or VRF equipment, do not attempt to install, commission or service any Daikin VRV product with this handbook. Instead, the Field Service Technician needs to complete training offered by Daikin AC (Americas), Inc. ("Daikin AC") before attempting any installation, commissioning or service of the VRV product.
cash.
Product Highlights View AR View 360 Fresh air supply and better indoor air quality for confined space. Air flow rate 150 – 2,000 m³/hour Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin’s VRV system, SkyAir and other air conditioning systems and automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration. VAM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VAM Supply Air duct. Heat Recovery Ventilation with Simultaneous Supply and Exhaust A compact unit packed with Daikin’s cutting-edge technologies The heat exchange element uses a upgraded High Efficiency Paper HEP that has superior moisture-absorption and humidifying properties and doubles the current efficiency of moisture absorption. The heat exchange unit speedily recovers heat contained as latent heat vapor. The element is made of a material with superior flame-resistant properties and is treated with an anti-molding agent. Advanced Energy-Saving Ventilation by Interlocking with VRV Indoor Unit • Pre-cool, Pre-heat control • Auto-ventilation mode changeover switching • Night-time free cooling operation Air Conditioning Load Reduced by Approximately 31%* Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
daikin heat reclaim ventilator